Why Are Dry Type Transformers Preferred in High-Humidity Environments?

2026-09-17

1. What Specific Risks Does High Humidity Create for Oil-Filled Transformers?

An oil-filled transformer relies on mineral oil for two functions: insulation and cooling. In a high-humidity environment, both functions are compromised. The first risk is moisture ingress into the oil. Even with a sealed tank, breathing action caused by thermal cycling can draw moist air into the conservator tank. Over time, the oil absorbs water, which reduces its dielectric strength. A water content of just 30 ppm can reduce the breakdown voltage of mineral oil by 30 percent. The second risk is condensation on the windings. When the transformer cools, moisture in the air inside the tank can condense on the winding surfaces. This creates a path for partial discharge and eventual flashover. The third risk is external corrosion. The tank, cooling fins, and bushings are all exposed to humid air. Rust and pitting can lead to oil leaks and structural failure. In our factory, we have inspected oil-filled transformers from coastal installations that required oil replacement every 2 to 3 years because of moisture contamination.

Moisture equilibrium in oil: Mineral oil absorbs moisture from the air until equilibrium is reached. At 40°C and 90 percent relative humidity, the equilibrium water content of oil can reach 50 to 60 ppm. At this level, the dielectric strength is reduced by 40 to 50 percent compared to dry oil.

Lugao Power Co.,Ltd. manufactures Dry Type Transformer units that are specifically designed for high-humidity environments. Our transformers use cast resin insulation and a sealed winding structure that prevents moisture from reaching the conductive parts. We have supplied these transformers to coastal substations, offshore platforms, and underground metro stations.

SCB13 Copper Winding Dry Type Power Transformer


2. How Does the Insulation System of a Dry Type Transformer Resist Moisture?

The insulation system of a Dry Type Transformer is based on solid dielectric materials rather than liquid. The most common type is cast resin, in which the windings are encapsulated in an epoxy resin that is cured under vacuum. The vacuum casting process eliminates air voids and creates a hermetic seal around the winding. Moisture cannot penetrate the resin, and condensation cannot form on the winding surface because there is no air gap. The table below compares the moisture resistance of different transformer insulation systems.

Insulation system Moisture resistance Dielectric strength in humid air Maintenance requirement
Mineral oil (oil-filled) Poor (absorbs moisture) Reduced by 40-50% at 60 ppm water Oil testing and replacement every 2-3 years
Cast resin (dry type) Excellent (hermetic seal) Unaffected by humidity Cleaning every 1-2 years
Resin-impregnated paper (dry type) Good (sealed against moisture) Unaffected by humidity Cleaning every 1-2 years
Air-insulated (dry type) Moderate (requires heaters) Reduced in high humidity Heaters and regular inspection

Cast resin insulation provides the highest level of moisture resistance. The epoxy resin is hydrophobic, meaning it repels water. Even if the transformer is exposed to direct water spray, the insulation maintains its dielectric strength. Our factory tests every cast resin Dry Type Transformer with a water spray test per IEC 60076-11. The transformer must maintain full dielectric strength after the test.


3. What Are the Key Parameters to Verify When Selecting a Dry Type Transformer for High Humidity?

When selecting a Dry Type Transformer for a high-humidity environment, there are five key parameters to verify. The first is the insulation class. Class F (155°C) or Class H (180°C) insulation provides a higher temperature margin, which is important because high humidity can reduce the cooling efficiency of the air. The second is the ingress protection rating. An IP54 rating ensures that the enclosure is protected against dust and water splashes. The third is the anti-condensation heater. Even a dry type transformer can benefit from a heater to prevent condensation on the enclosure and the terminals during rapid temperature changes. The fourth is the winding material. Copper windings are preferred over aluminum because copper has lower resistance and better thermal conductivity. The fifth is the temperature rise. A lower temperature rise (e.g., 80K instead of 100K) reduces the thermal stress on the insulation and extends the service life. The table below shows the specifications of our standard dry type transformer models for high-humidity applications.

Parameter Model SCB-500 Model SCB-1000 Model SCB-2000
Rated capacity (kVA) 500 1000 2000
Insulation class Class F (155°C) Class F (155°C) Class H (180°C)
Temperature rise 80K 80K 100K
Ingress protection IP54 IP54 IP54
Anti-condensation heater Standard Standard Standard
Winding material Copper Copper Copper

Lugao Power Co.,Ltd. manufactures Dry Type Transformer units with these specifications. Our factory uses vacuum casting for the windings and a corrosion-resistant enclosure for the humid environment. We also offer a stainless steel enclosure for coastal installations.


4. What Maintenance Practices Extend the Life of a Dry Type Transformer in Humid Conditions?

Although a Dry Type Transformer requires less maintenance than an oil-filled unit, it still requires periodic attention to ensure reliable operation in a humid environment. The most important maintenance task is cleaning. Dust and moisture can combine to form a conductive film on the insulation surface, which can lead to tracking. We recommend cleaning the windings and the enclosure every 12 months using a vacuum cleaner and a dry cloth. Do not use water or solvents. The second task is checking the anti-condensation heater. The heater should be operational whenever the transformer is de-energized. The third task is inspecting the terminals for corrosion. If corrosion is found, clean the terminals and apply a protective coating. The fourth task is checking the tightness of the electrical connections. Thermal cycling can cause connections to loosen over time. We recommend retorquing the connections annually to the specified torque values. In our factory, we provide a maintenance manual with every Dry Type Transformer that includes a checklist for humid environment installations.


Frequently Asked Questions About Dry Type Transformers in High-Humidity Environments

Question 1: Can a dry type transformer be installed outdoors in a coastal environment?
Answer: Yes, a Dry Type Transformer can be installed outdoors in a coastal environment, but the enclosure must be designed for the conditions. We recommend an IP54 or IP55 enclosure with a stainless steel or hot-dip galvanized finish. The windings should be cast resin with a hydrophobic surface. The bushings should be silicone rubber, which resists salt fog. In our factory, we have supplied outdoor dry type transformers to coastal installations in Southeast Asia and the Middle East. These units have been in service for over 8 years without moisture-related failures. We also recommend installing the transformer in a shaded area or providing a sun shield to reduce the internal temperature.
Question 2: How does the efficiency of a dry type transformer compare to an oil-filled transformer in humid conditions?
Answer: In humid conditions, a dry type transformer may have a slightly lower efficiency than an oil-filled transformer of the same rating because air cooling is less effective than oil cooling. However, this difference is typically less than 1 percent. More importantly, the efficiency of the oil-filled transformer degrades over time as the oil absorbs moisture and the cooling efficiency decreases. The dry type transformer maintains its efficiency because the insulation system is not affected by moisture. In our factory, we have measured the efficiency of our dry type transformers over a 10-year period. The efficiency remained within 0.5 percent of the initial value, while the oil-filled units in the same facility showed a 2 to 3 percent degradation due to oil contamination.
Question 3: What is the maximum humidity level that a dry type transformer can withstand?
Answer: A cast resin Dry Type Transformer can withstand up to 100 percent relative humidity without any reduction in dielectric strength. The cast resin insulation is hermetic and hydrophobic. The limitation is not the transformer itself but the enclosure and the terminals. If the enclosure is not properly sealed, condensation can form on the terminals and cause corrosion. We recommend an IP54 enclosure for humidity levels up to 95 percent and an IP55 enclosure for higher levels. The anti-condensation heater should be used whenever the transformer is not energized. In our factory, we test our dry type transformers in a humidity chamber at 95 percent relative humidity and 40°C for 1000 hours. The insulation resistance remains above 1000 MΩ throughout the test.

Summary for Electrical Design Engineers

Dry Type Transformer units are the preferred choice for high-humidity environments because they eliminate the moisture-related failure modes of oil-filled transformers. The cast resin insulation system is hermetic and hydrophobic, so it does not absorb moisture or allow condensation on the windings. The key parameters to verify are the insulation class, the ingress protection rating, the anti-condensation heater, and the winding material. With proper maintenance, a dry type transformer can provide decades of reliable service in the most demanding humid environments. Lugao Power Co.,Ltd. has been manufacturing Dry Type Transformer units for over 15 years and supplies to projects in more than 30 countries.

Lugao Power Co.,Ltd. manufactures cast resin Dry Type Transformer units with IP54 or IP55 enclosures, copper windings, and anti-condensation heaters. We provide full test reports and installation support for high-humidity applications.

Need help selecting a dry type transformer for a high-humidity installation? Contact Lugao Power Co.,Ltd. for a free consultation. We will review your environmental conditions and recommend the optimal transformer configuration.